RFOU ( C ) Instrumentation Cable to IEC 60092-376 & NEK 606
Designed for use in petrochemical and offshore instrumentation applications RFOU is available in collectively or individually screened options for optimum EMI suppression. The NEK 606 rated Low Smoke Halogen Free sheath offers resistance to MUD and drilling oils and meets the flame retardance requirements of IEC 60332-3-22 Cat A. This makes RFOU the ideal choice for safe areas and where personnel or equipment may be at risk from smoke damage in the event of a fire.
Tinned stranded copper conductor, EPR insulation, overall screen of copper backed polyester tape with a stranded copper drain wire, inner sheath of halogen free thermoplastic elastomeric, tinned copper wire braid armour, MUD resistant LSHF elastomeric sheath. The individually screened version has a copper backed polyester tape with a stranded copper drain wire around each pair or triple.
Image representative of product style, product supplied may vary.
- NEK 606 Design
- MUD Resistant
- Flame Retardant
Voltage Rating: | 250V |
Conductor Stranding: | IEC 60228 Class 2, tinned copper |
Temperature Rating: | -40°C to +90°C |
Bending Radius Static: | 6 x overall diameter |
Oxygen Index of Sheath: | >31% |
Flame Retardant: | IEC 60332-1-2, IEC 60332-3-22 Cat A |
Smoke Emission: | IEC 61034-1 & 2 |
Halogen Emission: | IEC 60754-1 & 2 |
MUD Resistant: | NEK 606 Collective Screen S2/S6, Individual Screen S1/S5 |
Manufactured To: | IEC 60092-376, NEK 606 |
3rd Party Approvals: | DNV, approval may vary between manufacture brands. |
Conductor Size: | 0.75mm² | 1.5mm² |
Conductor Resistance: | <26.7 Ohms/km | <13.7 Ohms/km |
L/R Ratio: | 12.7mH/Ohm | 26.6mH/Ohm |
Mutual Capacitance @ 800Hz: | ||
Collective Screen: | 100nF/km | 110nF/km |
Individual Screen: | 110nF/km | 125nF/km |
Triples - Light blue, black, brown and numbered
Order by 4.30pm for delivery by
Code | Description | Armour | Screen | Colour | Sheath | Downloads | Pack Size | QTY | Price | ||
---|---|---|---|---|---|---|---|---|---|---|---|
RFC0070201 |
2 x 2 x 0.75mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Pairs Blue LSHF
|
TCWB | Overall Foil | Blue | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC0070205 |
2 x 2 x 0.75mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Pairs Grey LSHF
|
TCWB | Overall Foil | Grey | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC0150201 |
2 x 2 x 1.5mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Pairs Blue LSHF
|
TCWB | Overall Foil | Blue | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC0150205 |
2 x 2 x 1.5mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Pairs Grey LSHF
|
TCWB | Overall Foil | Grey | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC0070301 |
3 x 2 x 0.75mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Pairs Blue LSHF
|
TCWB | Overall Foil | Blue | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC0070305 |
3 x 2 x 0.75mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Pairs Grey LSHF
|
TCWB | Overall Foil | Grey | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC0150301 |
3 x 2 x 1.5mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Pairs Blue LSHF
|
TCWB | Overall Foil | Blue | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC0150305 |
3 x 2 x 1.5mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Pairs Grey LSHF
|
TCWB | Overall Foil | Grey | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC0070401 |
4 x 2 x 0.75mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Pairs Blue LSHF
|
TCWB | Overall Foil | Blue | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC0070405 |
4 x 2 x 0.75mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Pairs Grey LSHF
|
TCWB | Overall Foil | Grey | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC0150401 |
4 x 2 x 1.5mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Pairs Blue LSHF
|
TCWB | Overall Foil | Blue | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC0150405 |
4 x 2 x 1.5mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Pairs Grey LSHF
|
TCWB | Overall Foil | Grey | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC0070801 |
8 x 2 x 0.75mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Pairs Blue LSHF
|
TCWB | Overall Foil | Blue | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC0070805 |
8 x 2 x 0.75mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Pairs Grey LSHF
|
TCWB | Overall Foil | Grey | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC0150801 |
8 x 2 x 1.5mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Pairs Blue LSHF
|
TCWB | Overall Foil | Blue | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC0150805 |
8 x 2 x 1.5mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Pairs Grey LSHF
|
TCWB | Overall Foil | Grey | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC0071201 |
12 x 2 x 0.75mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Pairs Blue LSHF
|
TCWB | Overall Foil | Blue | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC0071205 |
12 x 2 x 0.75mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Pairs Grey LSHF
|
TCWB | Overall Foil | Grey | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC0151201 |
12 x 2 x 1.5mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Pairs Blue LSHF
|
TCWB | Overall Foil | Blue | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC0151205 |
12 x 2 x 1.5mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Pairs Grey LSHF
|
TCWB | Overall Foil | Grey | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC0071601 |
16 x 2 x 0.75mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Pairs Blue LSHF
|
TCWB | Overall Foil | Blue | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC0071605 |
16 x 2 x 0.75mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Pairs Grey LSHF
|
TCWB | Overall Foil | Grey | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC0151601 |
16 x 2 x 1.5mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Pairs Blue LSHF
|
TCWB | Overall Foil | Blue | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC0151605 |
16 x 2 x 1.5mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Pairs Grey LSHF
|
TCWB | Overall Foil | Grey | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC0072401 |
24 x 2 x 0.75mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Pairs Blue LSHF
|
TCWB | Overall Foil | Blue | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC0072405 |
24 x 2 x 0.75mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Pairs Grey LSHF
|
TCWB | Overall Foil | Grey | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC0152401 |
24 x 2 x 1.5mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Pairs Blue LSHF
|
TCWB | Overall Foil | Blue | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC0152405 |
24 x 2 x 1.5mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Pairs Grey LSHF
|
TCWB | Overall Foil | Grey | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC00702T01 |
2 x 3 x 0.75mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Triples Blue LSHF
|
TCWB | Overall Foil | Blue | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC00702T05 |
2 x 3 x 0.75mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Triples Grey LSHF
|
TCWB | Overall Foil | Grey | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC01502T01 |
2 x 3 x 1.5mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Triples Blue LSHF
|
TCWB | Overall Foil | Blue | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC01502T05 |
2 x 3 x 1.5mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Triples Grey LSHF
|
TCWB | Overall Foil | Grey | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC00703T01 |
3 x 3 x 0.75mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Triples Blue LSHF
|
TCWB | Overall Foil | Blue | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC00703T05 |
3 x 3 x 0.75mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Triples Grey LSHF
|
TCWB | Overall Foil | Grey | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC01503T01 |
3 x 3 x 1.5mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Triples Blue LSHF
|
TCWB | Overall Foil | Blue | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC01503T05 |
3 x 3 x 1.5mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Triples Grey LSHF
|
TCWB | Overall Foil | Grey | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC00704T01 |
4 x 3 x 0.75mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Triples Blue LSHF
|
TCWB | Overall Foil | Blue | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC00704T05 |
4 x 3 x 0.75mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Triples Grey LSHF
|
TCWB | Overall Foil | Grey | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC01504T01 |
4 x 3 x 1.5mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Triples Blue LSHF
|
TCWB | Overall Foil | Blue | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC01504T05 |
4 x 3 x 1.5mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Triples Grey LSHF
|
TCWB | Overall Foil | Grey | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC00708T01 |
8 x 3 x 0.75mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Triples Blue LSHF
|
TCWB | Overall Foil | Blue | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC00708T05 |
8 x 3 x 0.75mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Triples Grey LSHF
|
TCWB | Overall Foil | Grey | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC01508T01 |
8 x 3 x 1.5mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Triples Blue LSHF
|
TCWB | Overall Foil | Blue | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC01508T05 |
8 x 3 x 1.5mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Triples Grey LSHF
|
TCWB | Overall Foil | Grey | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC00712T01 |
12 x 3 x 0.75mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Triples Blue LSHF
|
TCWB | Overall Foil | Blue | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC00712T05 |
12 x 3 x 0.75mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Triples Grey LSHF
|
TCWB | Overall Foil | Grey | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC01512T01 |
12 x 3 x 1.5mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Triples Blue LSHF
|
TCWB | Overall Foil | Blue | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC01512T05 |
12 x 3 x 1.5mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Triples Grey LSHF
|
TCWB | Overall Foil | Grey | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC00716T01 |
16 x 3 x 0.75mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Triples Blue LSHF
|
TCWB | Overall Foil | Blue | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC00716T05 |
16 x 3 x 0.75mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Triples Grey LSHF
|
TCWB | Overall Foil | Grey | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC01516T01 |
16 x 3 x 1.5mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Triples Blue LSHF
|
TCWB | Overall Foil | Blue | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC01516T05 |
16 x 3 x 1.5mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Triples Grey LSHF
|
TCWB | Overall Foil | Grey | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC00724T01 |
24 x 3 x 0.75mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Triples Blue LSHF
|
TCWB | Overall Foil | Blue | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC00724T05 |
24 x 3 x 0.75mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Triples Grey LSHF
|
TCWB | Overall Foil | Grey | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC01524T01 |
24 x 3 x 1.5mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Triples Blue LSHF
|
TCWB | Overall Foil | Blue | LSHF | Get Quote | Get Quote | ||||
|
|||||||||||
RFC01524T05 |
24 x 3 x 1.5mm² RFOU Instrumentation to IEC 60092-376 Collectively Screened Triples Grey LSHF
|
TCWB | Overall Foil | Grey | LSHF | Get Quote | Get Quote | ||||
|
Please contact us to request a quote for this item.
RFOU ( C ) Instrumentation Cable to IEC 60092-376 & NEK 606
Part No. G1454A sales representative will contact you within 3 hours, Monday to Friday 8am - 5pm.
Alternatively contact us on 01727 840 841
Request sent
Continue ShoppingPeople also viewed…
- RFOU Power Cable to IEC 60092-353 & NEK 606Code: G1453
- BFOU Fire Resistant Power Cable to IEC 60092-353 & NEK 606Code: G1455
- BFOU ( C ) Fire Resistant Instrumentation Cable to IEC 60092-376 & NEK 606Code: G1456
- RFOU ( I ) Instrumentation Cable to IEC 60092-376 & NEK 606Code: G1551
- BFOU ( I ) Fire Resistant Instrumentation Cable to IEC 60092-376 & NEK 606Code: G1552